Goodman

Goodman R-32 3.0 Ton 80% AFUE Horizontal/Upflow Gas Split System - CHOOSE YOUR BTU AND COIL MATCHUP!

Write a Review
SKU:
BASE32184
MPN:
GLXS4BA3610
Weight:
400.00 LBS
Shipping:
Free Shipping
  • Goodman R-32 3.0 Ton 80% AFUE Horizontal/Upflow Gas Split System - CHOOSE YOUR BTU AND COIL MATCHUP!
  • Goodman R-32 3.0 Ton 80% AFUE Horizontal/Upflow Gas Split System - CHOOSE YOUR BTU AND COIL MATCHUP!
  • Goodman R-32 3.0 Ton 80% AFUE Horizontal/Upflow Gas Split System - CHOOSE YOUR BTU AND COIL MATCHUP!
  • Goodman R-32 3.0 Ton 80% AFUE Horizontal/Upflow Gas Split System - CHOOSE YOUR BTU AND COIL MATCHUP!
$2,309.00

Additional Discounts At Checkout On Select Items!

Description

Goodman R-32 3.0 Ton 80% Horizontal/Upflow Gas Split System - CHOOSE YOUR BTU AND COIL MATCHUP!

GLXS4BA3610 Matchup Code: F212-8C  
SEER2 Cooling BTU/h Decibels Compressor Stage Compressor Type Motor Type Motor Horsepower Liquid Line Size Suction Line Size Refrigerant Charge (oz.)
14.3 36,000 67 Single Scroll PSC 1/6 3/8 7/8 69
Volts/Phase (60Hz) M.C.A. M.O.P. Min/Max Volts Net Weight (lbs.) Gross Weight (lbs.) Dimensional Width (in.) Dimensional Depth (in.) Dimensional Height (in.)  
208/230-1 17.8 30 197/253 158 173 29 29 39.5
GR9S800603BN  
Upflow or Downflow Input Natural Gas Output LP Gas Output AFUE Temp. Rise Range (*F) Blower Wheel Diameter (in.) Blower Wheel Width (in.) Motor Horsepower Motor Speed
Upflow 60,000 48,000 48,000 80% 20-50 10 8 1/2 9
Vent Diameter (in.) No. of Burners M.C.A. M.O.P. Weight (lbs.) Dimensional Widht (in.) Dimensional Depth (in.) Dimensional Height (in.)  
4 3 8.7 15 100 17.5 28 33
CHPTA3630B3  
Tons Liquid Line Size Suction Line Size Weight (lbs.) Dimensional Width (in.) Dimensional Depth (in.) Dimensional Height (in.)  
2.5-3.0 3/8 7/8 66 30 21 17.5
GLXS4BA3610 Matchup Code: F216-5C          
SEER2 Cooling BTU/h Decibels Compressor Stage Compressor Type Motor Type Motor Horsepower Liquid Line Size Suction Line Size Refrigerant Charge (oz.)
14.3 36,000 67 Single Scroll PSC 1/6 3/8 7/8 69
Volts/Phase (60Hz) M.C.A. M.O.P. Min/Max Volts Net Weight (lbs.) Gross Weight (lbs.) Dimensional Width (in.) Dimensional Depth (in.) Dimensional Height (in.)  
208/230-1 17.8 30 197/253 158 173 29 29 39.5
GR9S800803BN  
Upflow or Downflow Input Natural Gas Output LP Gas Output AFUE Temp. Rise Range (*F) Blower Wheel Diameter (in.) Blower Wheel Width (in.) Motor Horsepower Motor Speed
Upflow 80,000 64,000 64,000 80% 35-65 10 8 1/2 9
Vent Diameter (in.) No. of Burners M.C.A. M.O.P. Weight (lbs.) Dimensional Widht (in.) Dimensional Depth (in.) Dimensional Height (in.)  
4 4 8.7 15 116 17.5 28 33
CHPTA3630B3  
Tons Liquid Line Size Suction Line Size Weight (lbs.) Dimensional Width (in.) Dimensional Depth (in.) Dimensional Height (in.)  
2.5-3.0 3/8 7/8 66 30 21 17.5
GLXS4BA3610 Matchup Code: F228-0C          
SEER2 Cooling BTU/h Decibels Compressor Stage Compressor Type Motor Type Motor Horsepower Liquid Line Size Suction Line Size Refrigerant Charge (oz.)
14.3 36,000 67 Single Scroll PSC 1/6 3/8 7/8 69
Volts/Phase (60Hz) M.C.A. M.O.P. Min/Max Volts Net Weight (lbs.) Gross Weight (lbs.) Dimensional Width (in.) Dimensional Depth (in.) Dimensional Height (in.)  
208/230-1 17.8 30 197/253 158 173 29 29 39.5
GR9S800804CN  
Upflow or Downflow Input Natural Gas Output LP Gas Output AFUE Temp. Rise Range (*F) Blower Wheel Diameter (in.) Blower Wheel Width (in.) Motor Horsepower Motor Speed
Upflow 80,000 64,000 64,000 80% 35-65 10 10 3/4 9
Vent Diameter (in.) No. of Burners M.C.A. M.O.P. Weight (lbs.) Dimensional Widht (in.) Dimensional Depth (in.) Dimensional Height (in.)  
4 4 12.45 15 132 21 28 33
CHPTA3630C3  
Tons Liquid Line Size Suction Line Size Weight (lbs.) Dimensional Width (in.) Dimensional Depth (in.) Dimensional Height (in.)  
2.5-3.0 3/8 7/8 70 30 21 21
GLXS4BA3610 Matchup Code: F240-1C          
SEER2 Cooling BTU/h Decibels Compressor Stage Compressor Type Motor Type Motor Horsepower Liquid Line Size Suction Line Size Refrigerant Charge (oz.)
14.3 36,000 67 Single Scroll PSC 1/6 3/8 7/8 69
Volts/Phase (60Hz) M.C.A. M.O.P. Min/Max Volts Net Weight (lbs.) Gross Weight (lbs.) Dimensional Width (in.) Dimensional Depth (in.) Dimensional Height (in.)  
208/230-1 17.8 30 197/253 158 173 29 29 39.5
GR9S801005CN  
Upflow or Downflow Input Natural Gas Output LP Gas Output AFUE Temp. Rise Range (*F) Blower Wheel Diameter (in.) Blower Wheel Width (in.) Motor Horsepower Motor Speed
Upflow 100,000 80,000 80,000 80% 35-65 10 10 3/4 9
Vent Diameter (in.) No. of Burners M.C.A. M.O.P. Weight (lbs.) Dimensional Widht (in.) Dimensional Depth (in.) Dimensional Height (in.)  
4 5 12.45 15 132 21 28 33
CHPTA3630C3  
Tons Liquid Line Size Suction Line Size Weight (lbs.) Dimensional Width (in.) Dimensional Depth (in.) Dimensional Height (in.)  
2.5-3.0 3/8 7/8 70 30 21 21
View AllClose